16

IP Media Server for HMP Demo Guide — July 2005

Preparing to Run the Demo

InBand – usually used with G.711 coders

RFC2833

Capability

Describes the transmit and receive coders. See the Global Call IP Technology Guide for
specific information about coder support. The parameters are as follows:

TxType – the transmit voice coder

Note: By default, the fax demo is turned off. This feature may be enabled when tested with

T.38 capable IP endpoints. To do this, “uncomment” the line

TxType = t38UDPFax

in this section by removing the # from the start of the line, or add the line if not
present.

TxFramesPerPkt – the number of frames per packet for the selected Tx coder

TxVAD – specifies if VAD is active for the selected Tx coder

RxType – the receive voice coder

RxFramesPerPkt – the number of frames per packet for the selected Rx coder

Note: The G.711 coder defines frames per packet using the packet size in milliseconds, i.e.

10, 20, or 30 milliseconds. Refer to the

Sample Configuration File

, below, for the

correct syntax for all the parameters.

RxVAD – specifies if VAD is active for the selected Rx coder

Quality of Service

The application can set threshold values to monitor the quality of service during calls. A fault
occurs when the result of a measurement of a QoS parameter crosses a predefined threshold. A
success occurs when the result of a measurement of a QoS parameter dis not cross a predefined
threshold. The QoS parameters are measured during time intervals, starting when a call is
established. The following parameters are supported:

MediaAlarmLostPackets – monitors the number of lost IP packets during a call

MediaAlarmJitter – monitors the jitter (as defined in RFC 1889) during IP transmission

QoS Attributes

The threshold for each QoS parameter is measured with the following six attributes:

Threshold – defines when a QoS parameter is in a fault condition. A fault occurs when the
result of a measurement of a QoS parameter crossed the Threshold value.

DebounceOn – the time during which faults are measured (in msec., must be multiple of
Interval)

DebounceOff – the time during which successes are measured (in msec., must be multiple
of Interval)

Interval – the amount of time between two QoS parameter measurements (in multiples of
100 msec)

Percent_Fail – used to detect failure condition, together with DebounceOn (expressed as
a percentage of failures)

Percent_Success – used to detect failure recovery, together with DebounceOff (expressed
as a percentage of successes)

The default values are as follows:

QoS Type

Threshold

DebounceOn

DebounceOff

Interval

Percent_

Fail

Percent_

Success

Lost packets

20

10000

10000

1000

60

40

Jitter

60

20000

60000

5000

60

40