Table 2-3 Error Symptoms List

Error Symptoms

Action/FRU

NOTE:

To diagnose a problem, first find the error symptom

in the left column. If directed to a check procedure, replace the
FRU indicated in the check procedure. If no check procedure
is indicated, the first Action/FRU listed in right column is the
most likely cause.

Display problem:

- Incorrect colors
- No high intensity
- Missing, broken,
or
incorrect
characters
- Blank
monitor(dark)
- Blank
monitor(bright)
- Distorted image
- Unreadable
monitor
- Other monitor
problems

Monitor signal connection/cable.

Monitor

System board

Display changing

colors.

Monitor signal connection/cable

Monitor

System board

Display problem not

listed above
(including blank or
illegible monitor).

"Monitor" on page 102.

Load default settings (if screen is

readable).

System board

Parallel

NOTE:

Execute “Load BIOS Default Settings” in BIOS Setup

to confirm ports’ presence before diagnosing any parallel/serial
ports problems.

Serial or parallel port

loop-back test
failed.

Make sure that the LPT# or COM# you

test is the same as is set in BIOS
Setup.

Loop-back.

System board.