IMC Networks FAIL-SAFE MOR-F-632-120-EB82 User Manual

Page 14

Advertising
background image

10

Installation Instructions

Each IE-iMcV-E1-Mux/4 module requires two adjacent slots in an iMediaChassis or
MediaChassis. To install the module in a chassis, remove the blank faceplates
covering the slots where the module is to be installed. Then slide the module into
the chassis card guides until the module is seated securely in the slots. Secure the
module to the chassis by tightening the captive screw.

All IE-iMcV-E1-Mux/4 units are shipped from the factory configured as Host units.
The IE-iMcV-E1-Mux/4 modules must be installed in pairs. For two IE-iMcV-E1-
Mux/4 units to properly operate together one unit needs to be configured as a
Remote. Configuration as a Host or Remote is controlled via a DIP switch setting (S1-
1).

Small Form-Factor Pluggable Ports (SFP)

The fiber link on the IE-iMcV-E1-Mux/4 module is supported through one or two SFPs
(depending on the model) running at 155Mbps. Many SFPs, including those from
IMC Networks, feature enhanced diagnostics capabilities DDMI (Data and Diagnostic
Management Information). DDMI statistics provide real-time access to transceiver
operating parameters such as voltage, temperature, laser bias current, and both
transmitted and received optical power. DDMI information can be accessed in
iView

2

.

AutoCross Feature

The 10/100BaseT Ethernet port on the IE-iMcV-E1-Mux/4 includes an AutoCross
feature that automatically selects between a crossover workstation and a straight-
through connection depending on the connected device.