Intel® RAID Controller SRCSAS144E Hardware Guide

12

Replacing a Controller

Perform the following steps to replace a failed controller.

1. Power off the computer and all drives, enclosures, and system components. Remove

the power cord.

2. Remove the chassis cover and access the PCI Express add-in card slots. See your

server documentation for instructions.

3. Disconnect the cable(s) from the RAID controller.
4. Remove the failed controller from the system.
5. Insert the replacement controller into the system. Follow the instructions under

Installation

.

Resolving a Configuration Mismatch

If a replacement RAID Controller SRCSAS144E has a previous configuration, a message
displays during POST stating that there is a configuration mismatch. A configuration
mismatch occurs when the configuration data in the NVRAM and the hard disk drives
are different. You need to update the configuration data in the NVRAM with the data
from the hard disk drive.

Perform the following steps to resolve the mismatch.

1. Press <Ctrl> <G> when prompted during the boot process to access the BIOS

Configuration Utility.

2. Select Configure—>View/Add Configuration. This allows viewing of the NVRAM

and drive configurations.

3. Select the configuration on disk because the drives contain the correct configuration.
4. Press <Esc> and select YES to update the NVRAM.
5. Exit and reboot.