Fault tolerance, Electrical characteristics, Fault tolerance electrical characteristics – Intel raid controller srcsas144e User Manual

Page 25

Advertising
background image

Intel® RAID Controller SRCSAS144E Hardware Guide

16

Fault Tolerance

Table 4 shows the RAID Controller SRCSAS144E fault tolerance features.

Electrical Characteristics

This section provides the power requirements for the RAID Controller SRCSAS144Es.

Table 5 lists the maximum power requirements.

Table 4. Fault Tolerance Features

Specification

Intel

®

RAID Controller SRCSAS144E

Self Monitoring

Analysis and Reporting

Technology (SMART)

support

Detects up to 70% of all predictable disk drive failures and monitors the

internal performance of all motors, heads, and drive electronics.

Optional Battery

Backup

Intel

®

RAID Smart Battery cache backup. Up to 64 hours of data

retention. Trickle / fast charging. Charge indicator.

Drive Replacement

Auto detection of hard drive failure; hot-plug, hot-swap. User set rebuild

rate.

Drive Rebuild Using

Hot Spares

Automatic at drive failure; dedicated per array; global per array; auto-

resume of initialization or rebuild on reboot

Error Checking and

Indication

Parity generation and checking, automatic consistency checking; patrol

reads; activity and fault LEDs

Power Conservation

Staggered spin-up, lower power requirements.

Table 5. Electrical Characteristics

PCI / PCI Express*

/ Express +12 V

PCI / +5.0 V

PCI / PCI

Express /

Express

+3.3 V

PCI PRSNT1# / 2#

Power

Operating

Range

Temperature

115 mA; used only if

battery is present

1.5 A

(PCI only)

N/A

15.6 W

18.3 W with battery

charging

0° C to 45° C

Advertising