Fig. 5

3. Shutdown

(1) Push the knob of the pressure switch to “OFF”

(Refer to Fig. 1 and Fig. 2).

(2) Unplug the plug from power source.
(3) Open the drain cock located at the lower part of

the tank (Fig. 6).

MAINTENANCE

WARNING:

Disconnect the compressor from the

power source and remove the
compressed air from the air tank
before performing the maintenance
operations. Allow the compressor to
cool before performing the
maintenance operations.

1. Cleaning the intake filter

Remove the intake filter (Refer to Fig. 1) every 50
hours or once a week and clean the inside of the
intake filter and the filter element with compressed air
(Fig. 7).
Use a phillips screwdriver to disassemble intake filter.

WARNING:

Never clean filter element with a

flammable liquid or solvent.

CAUTION :

Do not operate without the intake
filter.

Fig. 7

NOTE: Replace the filter element when it becomes dirty.

2. Draining tank

Drain tank daily or after 4 hours of use. Open drain
fitting and tilt compressor to empty accumulated
water (Refer to Fig. 6).

3. Oil change-oil topping off
(Only for EC12)

CAUTION :

Overfilling with oil will cause
premature compressor failure. Do not
overfill.

(1) Within the first 50 hours of operation, completely

replace the oil of the pumping element. Unfasten
the oil drain cap on the casing cover, drain all the
oil, and screw the cap back on (Refer to Fig. 8 ).

EC 10SB(SL)

EC 12

Knob of the
pressure switch

Pressure gauge (A)
indicates the pressure
in the air tank

Pressure gauge (B)
indicates the working
pressure

Knob of the pressure reducer

Knob of the pressure switch

Knob of the
pressure
reducer

Pressure gauge (A)
indicates the pressure
in the air tank

Pressure gauge (B)
indicates the working
pressure

Tank

Drain cock

Fig. 6