Tumbler enclosure, Warning – IPSO 120 User Manual

Page 11

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Tumblers – 120 and 170

10

4-08-45

Tumbler Enclosure

Figure 1

TMB2020N

NOTE: Shaded areas indicate adjacent structure.

1

0.5 in. (13 mm) recommended between machines for removal or installation.

2

Allow 2-4 in. (51-102 mm) opening at top of machine to aid in removal or installation. A removable trim piece
may be used to conceal the opening; zero clearance allowed for trim.

3

4 in. (102 mm) maximum header thickness

4

Minimum clearance permitted for remainder: Gas 4 in. (102 mm), Steam 12 in. (305 mm)

5

Guard

6

Provision for Make-Up Air

7

24 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes

8

0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed

TMB2020N

4

1

5

6

7

3

WARNING

To reduce the risk of severe injury, clearance of tumbler cabinet from combustible

construction must conform to the minimum clearances.

W056

8

2

Advertising
This manual is related to the following products:

170