Updating Firmware from AIX

You must delete the file /var/update_flash_image before proceeding.

The flash update image file must have already been placed in the /var file system.
This could have been done with a file transfer from another server or with the
dosread command of the AIX DOS Utilities. For example, with the flash update
image in place, issuing the following AIX command

shutdown -u /var/ᑍfilenameᑍ.img

initiates the update process. Where *filename* is the name of the flash update
image. During the process, the server powers down and reboots. The process is
complete when the login prompt reappears.

Service Processor Logs

Service Processor Error Log:

The Service Processor error logs contain error

conditions detected by the Service Processor.

Error Log

1997 626223337

. Loss of Redundant Fan #5

4 21

91

Press "C" to clear error log, any other key to continue.

>

The time stamp in this error log is Coordinated Universal Time (CUT), a.k.a.
Greenwich Mean Time (GMT). AIX error logs have more information available and
are able to time stamp with local time.