Intel 80L186EA User Manual

Page 28

Advertising
background image

80C186EA 80C188EA 80L186EA 80L188EA

AC SPECIFICATIONS

AC Characteristics

80L186EA13 80L186EA8

Symbol

Parameter

Min

Max

Min

Max

Units

Notes

SYNCHRONOUS INPUTS

13 MHz

8 MHz

T

CHIS

TEST NMI INT3 0 T1 0IN ARDY

22

22

ns

1 9

T

CHIH

TEST NMI INT3 0 T1 0IN ARDY

3

3

ns

1 9

T

CLIS

AD15 0 (AD7 0) ARDY SRDY DRQ1 0

22

22

ns

1 10

T

CLIH

AD15 0 (AD7 0) ARDY SRDY DRQ1 0

3

3

ns

1 10

T

CLIS

HOLD

22

22

ns

1 9

T

CLIH

HOLD

3

3

ns

1 9

T

CLIS

RESIN (to CLKIN)

22

22

ns

1 9

T

CLIH

RESIN (from CLKIN)

3

3

ns

1 9

NOTES
1 See AC Timing Waveforms for waveforms and definition
2 Measured at V

IH

for high time V

IL

for low time

3 Only required to guarantee I

CC

Maximum limits are bounded by T

C

T

CH

and T

CL

4 Specified for a 50 pF load see Figure 13 for capacitive derating information
5 Specified for a 50 pF load see Figure 14 for rise and fall times outside 50 pF
6 See Figure 14 for rise and fall times
7 T

CHOV1

applies to BHE (RFSH) LOCK and A19 16 only after a HOLD release

8 T

CHOV2

applies to RD and WR only after a HOLD release

9 Setup and Hold are required to guarantee recognition
10 Setup and Hold are required for proper operation
11 T

CHOVS

applies to BHE (RFSH) and A19 16 only after a HOLD release

12 Pin names in parentheses apply to the 80C188EA 80L188EA

28

28

Advertising