Connecting to the S/PDIF Header

Before connecting to the S/PDIF connector, observe the precautions in "Before You
Begin" on page 23.
See Figure 12, B on page 34 for the location of the S/PDIF header.
Table 8 shows the pin assignments for the S/PDIF header.

Table 8. S/PDIF Header

Pin Signal

Name

1 Ground
2 S/PDIF

out

3 VCC

(5V)

Connecting to the Serial Headers

Before connecting to the serial headers, observe the precautions in "Before You Begin"
on page 23. See
Figure 12, C on page 34 for the location of the serial headers.
Table 9 shows the pin assignments for the serial headers.

Table 9. Serial Port Headers (COM 1 and COM 2)

Pin

Signal Name

Pin

Signal Name

1

DCD (Data Carrier Detect)

2

RXD# (Receive Data)

3

TXD# (Transmit Data)

4

DTR (Data Terminal Ready)

5

Ground

6

DSR (Data Set Ready)

7

RTS (Request To Send)

8

CTS (Clear To Send)

9

RI (Ring Indicator)

10

Key (no pin)

Connecting to the Parallel Port Header

Before connecting to the parallel port header, observe the precautions in "Before You
Begin" on page 23.
See Figure 12, D on page 34 for the location of the parallel port
header.
Table 10 shows the pin assignments for the parallel port header.

Table 10. Parallel Port Header

Pin

Standard Signal Name

ECP Signal Name

EPP Signal Name

1

STROBE# STROBE# WRITE#

2 AUTOFD#

AUTOFD#,

HOSACK

DATASTB#

3

PD0 PD0 PD0

4 FAULT#

FAULT#,

PERIPHREQST# FAULT#

5

PD1 PD1 PD1

6 INT#

INT#,

REVERSERQST# RESET#

7

PD2 PD2 PD2

8

SLCTIN# SLCTIN# ADDRSTB#

Advertising