Bios front-panel power led blink codes, Post error messages – Intel D510MO User Manual

Page 54

Advertising
background image

Intel Desktop Board D510MO Product Guide

54

BIOS Front-panel Power LED Blink Codes

The BIOS also blinks the front-panel power LED to signal status messages and error
messages indicating certain recoverable errors that occur during the POST. The blink
codes are listed in Table 18.

Table 18. BIOS Front-panel Power LED Blink Codes

Type

Pattern

Note

BIOS update in
progress

Off when the update begins, then on for
0.5 second, and then off for 0.5 second.
The pattern repeats until the BIOS update
is complete.

Video error

On-off (1.0 second each) two times, then a
2.5-second pause (off); the entire pattern
repeats (blinks and pause) until the system
is powered off.

When no VGA option ROM
is found.

Memory error

On-off (1.0 second each) three times, then
a 2.5-second pause (off); the entire pattern
repeats (blinks and pause) until the system
is powered off.

Thermal trip warning Each beep will be accompanied by the

following blink pattern: 0.25 second on,
0.25 second off, 0.25 second on,
0.25 second off. This results in a total of
16 blinks followed by system shut down.

POST Error Messages

The BIOS also displays error messages on the video monitor when certain recoverable
errors occur during the POST. Table 19 lists the error messages with a brief
description of each.

Table 19. POST Error Messages

Error Message

Explanation

CMOS Battery Low

The battery may be losing power.

CMOS Checksum Bad

The CMOS checksum is incorrect. The CMOS memory
may have been corrupted. Run Setup to reset values.

Memory Size Decreased

Memory size has decreased since the last boot. If no
memory was removed, then memory may be bad.

No Boot Device Available

System did not find a device to boot.


Advertising