TM-1020 Series Progressive Scan Shutter Cameras

Operation

Model: TM-1020

Operation Mode: 15 Frames/Second

Master Clock: 40 MHz, M= 25 nsec
Pixel Clock: 20 MHz, P = 50 nsec

3. External Reset Timing

4. Async Reset Timing

External VD

Internal VD

FDV

Digital Data

Analog Video

VINIT Trigger

Internal VD

FDV

Digital Data

Analog Video

Horizontal Frequency: 15.748 KHz
1H = 63.50

sec

A [1050 H], (66.68 msec)

B [0 H], (470.0 ns)

C [9 H], (572.0 s)

D [1041 H], (66.10 ms)

E [ 1050 H], (66.68 ms)

F [0 H], (36 ns)

I [0 H], (260.0 ns)

L [0 H], (100 ns)

P [3 H], (190.5 s)

G [32 H], (2.030 ms)

J [32 H], (2.040 ms)

M [29 H], (1.880 ms)

N [3 H], (190.5 s)

H [1018 H], (64.64 ms)

K [1018 H], (64.64 ms)

O [1018 H], (64.64 ms)

S [1041 H], (66.10 ms)

T [ 1050 H], (66.68 ms)

Y [1018 H], (64.64 ms)

CC [1018 H], (64.64 ms)

Q [1 H], (68.00 s)

U [0 H], (32.00 ns)

AA [29 H], (1.880 ms)

X [32 H], (2.040 ms)

BB [3 H], (190.5 s)

DD [3 H], (190.5 s)

W [9 H], (568.0 s)

Z [0 H], (5 s)

R [9 H], (572.0 s)

V [32 H], (2.040 ms)

Advertising