Page 35

TM-1020 Series Progressive Scan Shutter Cameras

LVDS-Version Camera RS-232 Commands

Note: One byte of data consists of two ASCII codes. For example, 0x3A is “3” (0x33). “A”

(0x41) x <ACK> is 0x06. <NAK> is 0x15.

This command’s basic protocol is the same for Camera Link model cameras.

7

“T” (Table)

“N” (kNee)

X1 + Y1 +
X2 + Y2

ACK

(X1, Y1) coordinate for knee 1

X1, Y1, X2,
Y2: “00 - FF”

(X2, Y2) coordinate for knee 2

“M” (Gamma)

ACK

“L” (Linear)

ACK

“C” (Switch A,
B Table)

“0” or “1”

ACK

8

“N”

“0” (Normal)

ACK

Normal Scan Formal

“1” (Binning)

ACK

Double Speed Binning

First

Character

Second

Character

Third

Character

Response

Functions

Advertising