6.2.5. Timing for window of interest
With WS=1, the X and Y start coordinates (WX and WY), and the width and height (WW and WH)
for the window of interest can be programmed with 1 pixel interval. The minimum window size

is 2(h) x 3 (v). If the window is specified outside the full image area, it will be placed up to the
right or low limit as shown in fig 17. right.

Figures marked with (*) in the timing diagrams below will change with other window settings.

(0, 0)

(658, 492)

Active Pixel Array

659

493

120

240

(200, 100)

(0, 0)

(658, 492)

Active Pixel Array

659

493

100

100

(559, 393)

Readout Region
(WX=559, WY=393, WW=100, WH=100)

Specifyed Region
(WX=600, WY=400, WW=100, WH=100)

Fig. 17. Window of interest.

1 LVAL = 16.825 µs

LVAL

DATA OUT

FVAL

Ef f ect i ve Li nes

21

6

21

5

……

120L( *)

125L( *)

129L( *)

……

1 FVAL per i od

21

7

21

9

21

8

DVAL

4L

……

5L

4L

10

0

10

1

10

2

10

3

10

4

10

0

10

1

10

2

10

3

10

4

( *) Var i abl e Number

Fig. 18. Vertical timing for window of interest.



DATA OUT

LVAL

Ef f ect i ve Pi xel s

……

240ck( *)

668ck

673ck

1 LVAL per i od

DVAL

5ck

9ck

9ck

5ck

200ck( *)

43

7

43

8

43

9

20

0

20

1

20

2

……

219ck( *)

( *) Var i abl e Number

1 ck = 25 nsec

Fig. 19. Horizontal timing for window of interest.