Input and output circuits, Trigger input, Een output – JAI CV-A33CL User Manual

Page 6: Cv-a33cl

Advertising
background image

CV-A33CL

5.3. Input and Output Circuits

5.3.1. Trigger input
The trigger inputs on pin #10 12 pin Hirose
connector is AC coupled. To allow a long pulse
width, the input circuit is a flip flop, which is

toggled by the negative or positive
differentiated spikes caused by the falling or
rising trigger edges.

GND

+5V

15k

TTL

1k

GND

100n

1k

68k

100k

1n

Trig input

pin #10

75Ω

SW 300

GND

+5V

15k

TTL

1k

GND

100n

1k

68k

100k

1n

Trig input

pin #10

75Ω

SW 300

The trigger polarity can be changed.
Trigger input level 4 V ±2 V. It can be 75Ω
terminated by internal SW300 on PK8388A.
The trigger inputs can be changed to
Camera Link input. (TI=0 for CL)

Fig. 4. Trigger input.

5.3.2. EEN output

GND

+5V

2
2

10k

2k2

75

TTL

100

#9/12

EEN output

GND

+5V

2
2

10k

2k2

75

TTL

100

#9/12

EEN output

On pin #9 on 12 pin HR connector EEN The output
circuit is 75 Ω complementary emitter followers. It
will deliver a full 5 volt signal.
Output level ≥4 V from 75Ω. (No termination).
EEN is also found in Camera Link.


Fig. 5. EEN output