Blower Kit Contents:

• Blower with mounting bracket
• Snapstat and Wiring Harness
• Hi/Low/Off Switch
• two 6mm bolts

Attach the Blower

1. Locate the two raised bosses on the bottom back

of the stove. See Figure 19. The blower is
mounted to the stove using these two threaded
holes.

2. With the blower bracket and snapstat facing

upward, align the two middle mounting holes
on the bracket with the two threaded holes on
the bottom back of the stove.

3. Use the two 6mm bolts to attach the blower to

the stove. Be sure to tighten the bolts so that
the blower is drawn upward and tight against
the stove bottom.

4. The snapstat (thermodisc), attached to the

blower bracket, should be inserted under the
stove bottom to make contact with the firebox!

Connect the Blower Wiring Harness

1. Lift off the stove top plate.
2. Loosen (

BUT

DO

NOT

REMOVE

) the 10 mm bolt holding

the switch box to the side of the stove (left rear
corner of the stove), and lift out the switch box.

3. Remove the “blank” switch from the box. (Hint:

break the retaining tabs holding the switch in the
box.)

4. Insert the new HI/OFF/LO switch into the box.
5. Connect the insulated wires from the blower to

three leads on the HI/OFF/LO switch. BLACK wire
to the HI position, WHITE wire to the OFF position,
and the RED wire to the LO position. See Fig. 22.

6. Reattach the switch box to the side of the stove.

Be sure all wires are unobstructed.

7. Replace top plate.

Figure 19. Blower and gas line installation.

Blower

90° elbow installed

directly off valve to

avoid blower

Gas Line

Figure 20. Blower attachment points.

The blower will ONLY come on when the switch is in
the Hi or Low position and ONLY when the snapstat
(thermodisc) is heated by the operation of the stove.
(Approximately 10- 20 minutes after the stove has
been running).

IMPORTANT: IF THE OPTIONAL

FORCED BLOWER KIT(PART # 129161)

IS TO BE INSTALLED ON THE STOVE

AT THE TIME OF THE INSTALLATION

OR IN THE FUTURE, THE GAS SUPPLY

LINE SHOULD BE INSTALLED AS

CLOSE TO THE FLOOR AS POSSIBLE.

USE OF A 90° DIRECTLY OFF THE

VALVE WILL ALLOW FOR PROPER

CLEARANCE FOR THE BLOWER. SEE

FIG. 18.