Horizontal venting requirements – Jotul GF3 DVII User Manual

Page 9

Advertising
background image

Restrictor Sliders

First Restriction
Setting
- install
screw into the
OUTER hole of
sliders.

Second Restriction
Setting
- screw
installed into
MIDDLE hole of
slider.

12

12

12

12

12

Figure 5. Vent restrictor settings.

Horizontal Venting Requirements

Follow these guidelines if any part of the installation

incorporates a horizontal run or terminates horizontally.

• The maximum horizontal run made directly off the

rear of the stove shall be no more than 12" and must
then be connected to a 14" snorkel cap (Simpson Dura-
vent #982).

• The horizontal termination cap must maintain a 3"

clearance to any overhead combustible projections
exceeding 2 1/2" or less. Maintain 12" clearance from
projections exceeding 2 1/2". See Figure 8, page for
complete termination clearance information.

• Any horizontal run of vent must be level or have a 1/

4" rise for every foot of run toward the termination
cap.

NEVER ALLOW THE VENTING TO SLOPE DOWNWARD,

AS HIGH TEMPERATURES MAY RESULT AND CREATE A
HAZARDOUS CONDITION.

• Vent Pipe Clearance to Combustible Materials: For all

horizontal runs, a 2" top clearance and a 1" side and
bottom clearance must be maintained.

Wall Pass-through: A minimum 10" X 10" square

cutout is required to maintain proper clearances
through combustible wall construction. The opening
must be framed in. Simpson Dura-Vent Wall Thimble
#942 or Secure Vent Wall Radiation Shield SV4RSM
must be used for the wall pass-through. Optional
decorative plates are available to finish the interior
side of the wall pass-through.

• IMPORTANT: Follow the vent manufacturer’s installa-

tion instructions provided with each vent component.

• DO NOT FILL AIR SPACE WITH ANY TYPE OF INSULATION.
• MAINTAIN THE PROPER CLEARANCES TO THE TERMI-

NATION CAP. SEE FIG. 10.

• Do not recess the termination cap into a wall or

siding.

• Install a Vinyl Siding Standoff between the vent cap

and the exterior wall (Simpson Dura-Vent #950). to
protect vinyl siding from overheating.

Figure 6. Minimum Vertical Vent - Simpson Dura-
Vent part numbers shown.

7

NOTE:
SHORT LEGS
REDUCE THE
HEIGHT BY
2 1/4”.

24” length

#904B

90° Elbow

#990B

55 3/4”

Floor to

centerline of

minimum

vertical rise

123

123

123

123

123

123

123

Figure 7. Horizontal terminal to corner.

Simpson Dura-Vent 45°

Elbow #945B

12” Max.
Horizontal run
into a 14”
Snorkel
Simpson Dura-
Vent (#906B)

14” Snorkel

Simpson

Dura-Vent

(#982)

12” Max. Horizontal
run into a 14” Snorkel
Simpson Dura-Vent
(#906B)

Figure 7a. Horizontal terminal directly off stove
must use a 14” Snorkel termination.

Rear Exit

Centerline

24 3/4”

628 mm

Wall

Thimble

#942B

Horizontal Length

12” Max.

Wall Plate

#940B