How to use external control, Cont'd), How to use the rs-485 terminal – JVC DT-V1910CG User Manual

Page 24

Advertising
background image

24

HOW TO USE THE RS-485 TERMINAL

You can control the monitor from the controller (exclusive for this monitor) or your PC via the RS-485 terminal. For details on
operating the monitor from the PC, consult the service center.

1. Cable

Prepare a straight cable with a D-sub connector (9-pin, male) and a D-sub
connector (9-pin, male)

2. Communications Specifications

Baud Rate

: 4800/9600/19200 (factory pre-set; 4800)

Data Bits

: 8 bits

Parity

: No parity

Stop Bits

: 1

Communication Cord : ASCII Cord

3. Commands

Format

Header ID Command ID Command Content Data CR

Header

!

Control from the PC to the monitor

?

Reference from the PC to the monitor

@

Answer from the monitor to the PC

ID + Command + Data

B

Basic command

Characters

00, 01 or No data

D

Command for adjusting the picture size

00 ~ 08

U, D (U: UP, D: DOWN)

S

Command for adjusting the picture quality

00 ~ 05

U, D (U: UP, D: DOWN)

M

Command for selecting the menu item

00 ~ 0E

00, 01, 10, 11

F

Command for selecting the menu item

00 ~ 10

00, 01, 02, 03, 04, 05

W

Command for adjusting the white balance

00 ~ 05

U, D (U: UP, D: DOWN)

C

Command for inquiring for the monitor’s status

00

0 ~ 655

Communication Procedures
The following is the communication procedures.

1. Starting the communication

Receives the connection command (!XXBCN1Cr) from the PC [ Sends the monitor’s status (@XXBOKCr) to the PC

2. Performing the external control

Receives the control command (!XXXXCr) from the PC [ Sends the monitor’s status (@XXBOKCr) to the PC
* The monitor repeats these receiving and sending if necessary.

3. Terminating the communication

Receives the termination command (!XXBCN0Cr) [ Sends the monitor’s status (@XXBOKCr) to the PC
* Hand-shake communication is used. This means that after sending a command to the monitor, the PC must receive a status

return from the monitor before sending the next command.

* When the monitor is controlled by a PC via RS-485, a conversion adapter (RS-232Cp[RS-485) is also required.

4

3

2
1

9
8

5

7

6

Pin No.

IN terminal

OUT terminal

signal

signal

1

5V Power (for

controller exclusively

NC

for this monitor)

2

TD

+

TD

+

3

RD

+

RD

+

4

NC

NC

5

NC

NC

6

NC

NC

7

TD–

TD–

8

RD–

RD–

9

NC

NC

* The 5V power supply of the 1st terminal is for the controller

exclusively for this monitor. Do not use it for other devices.

HOW TO USE EXTERNAL
CONTROL

(cont'd)

LCT1424-001A_EN_p18-32

11/4/03, 5:13 PM

24

Advertising