Burner ignition and auto-reignition, Required adjustments at time of installation – Jenn-Air JGCP430ADP User Manual

Page 11

Advertising
background image

11

Burner Ignition And
Auto-Reignition

This appliance is equipped for electronic auto-reignition by
means of a spark igniter located at the rear of each
burner. The burners are designed to light at any valve
rotation that admits sufficient gas flow to support a flame
and to automatically relight following a loss of flame due
to a draft or other adverse condition. This feature is
provided as a convenience and is not intended as a safety
feature.

This appliance has no air shutters. Primary air
adjustments are unnecessary. The burners are designed
to provide optimum aeration for all gases without air
shutters. When operating properly, burners should
produce clearly defined, even blue flames. If the flames
have yellow tips or are hazy and otherwise appear to
have insufficient air, obtain the services of a qualified
service technician.

Specified input rates are as shown below.

BURNER

LOCATION

Hi

Lo

Right Front

17K

1700

Right Rear

9.2K

1050

Left Front

17K

1700

Left Rear

5K

600

INPUT RATES - NATURAL GAS (BTU/HR)

JGCP430ADP

JGCP636ADP and JGCP648ADP

BURNER

LOCATION

Hi

Lo

Right Front

17K

1700

Right Rear

9.2K

1050

Center Front

9.2K

1050

Center Rear

5K

600

Left Front

17K

1700

Left Rear

5K

600

INPUT RATES - NATURAL GAS (BTU/HR)

Model JGCP648ADP includes 1300 Watt Electric
Griddle Accessory.

Required Adjustments At Time
Of Installation

The installation of this appliance must conform with local
codes, or in the absence of local codes, with the latest
edition of the National Fuel Gas Code ANSI Z223.1 USA
or current CAN/CGA-B149 INSTALLATION CODE.

V

This appliance was manufactured for use with Natural
Gas. If LP gas is the fuel of choice, follow the
conversion to LP procedure found in the installation
instructions.

V

Test all external connections for gas leaks. Never test
for gas leaks with an open flame.

V

Test all electrical connections.

Advertising
This manual is related to the following products: