B. Invert cap in appliance pressure regulator

With the appliance installed, identify the type of
appliance regulator on the unit and follow the
instructions in the appropriate illustration.

FIGURE 13

CONVERSION OF MAXITROL APPLIANCE

PRESSURE REGULATOR

FIGURE 14

CONVERSION OF HARPER-WYMAN APPLIANCE

PRESSURE REGULATOR

C. Low Flame Adjustment

This appliance is shipped from the factory with low
and medium flame settings adjusted for use with
natural gas. If further adjustment is necessary, or to
readjust for use with LP, proceed as follows:

1. Light burner and set control knob for low flame.

2. Remove control knob from valve stem.

CAUTION:

NEVER USE A METAL BLADE TO PRY

KNOB OFF. IF KNOB CANNOT BE EASILY
REMOVED, TUCK THE FOLDS OF A CLOTH
DISHTOWEL UNDER THE KNOB AND PULL THE
TOWEL OUTWARD WITH STEADY, EVEN
PRESSURE.

3. Insert a slender, thin-blade screwdriver into the

recess at center of valve stem and engage blade
with slot in adjusting screw.

4. Turn center stem adjusting screw to set flame size.

. . . clockwise to reduce
. . . counterclockwise to increase

5. Replace control knob when adjustment is

completed.

Proper adjustment will produce a stable, steady blue
flame of minimum size. The final adjustment should be
checked by turning knob from high to low several times
without extinguishing the flame.

This adjustment, at low setting, will automatically provide
the proper flame size at medium setting.

FIGURE 15

After Conversion Steps A, B and C have been completed,
check the appearance of each burner’s flame at the Hi
and Lo settings against figure 16. If the flames appear too
large or too small, review each step to make sure it was
completed correctly.

FIGURE 16

FLAME APPEARANCE AT HI, MED & LOW