Before carrying out any operation which requires to disassembly of the pump
(inspection, cleaning, seal replacement, etc.), the following preliminary operations have
to be carried out:

Switch off engine tension and disinsert electric connection.

Close valves on suction and outlet pipelines, in order to avoid the risk of inundation.

Use adequate protection for hands and face, if the pump contains liquids which are
hazardous to health (for example acids, solvents, etc.).

Consider whether the liquid which flows out of the pump when disassembling is
dangerous and arrange for adequate safety measures.

4.0

Transportation, receipt and transferring of
goods

4.1

Transportation

The packings of all AS pumps are defined when making the order. Unless prior arrangements
are given, goods will be packed only for transit conditions and not for long-term storage; in case
it should be necessary to store the pumps outside, you are requested to cover the pumps
appropriately in order to protect the electrical parts (motor) from rain, dust, humidity etc.

4.2

Receipt

Upon receipt of goods the integrity of the packaging must be verified in order to identify
possible damages to the content during transfer, and to claim immediately from the carrier.
Should any damage be ascertained, the following procedure must be observed:

Collect the goods with receipt.

Take the necessary pictures showing the damages.

Notify the carrier of the suffered damages, by registered airmail – including the
pictures taken.

4.3

Transferring

Carry the packed pumps as close as possible to the place of installation by means of appropriate
lifting devices and unpack them. During this operation take care, as unsteady parts could fall
down.

The material used for packing (wood, paper, cellophane, etc.) should be properly disposed of,
according to the corresponding rules in force in receiver’ s country.

After unpacking the pump, use special lifting belts and move the pump-motor-set to the place
of installation; never use the eyebolts on the motor to move the pump, as the eyebolts are for
moving the motor only.

In versions complete with shroud,
take the shroud off before moving the
pump-motor-set, in order to avoid
damages.