Setting manually, Setting electronically – John Lewis JLDW 1225 User Manual

Page 12

Advertising
background image

Water hardness

Adjustment of the water

softener

Use of salt

Clarke

°TH

mmol/l

manually

electronically

64 - 88

91 - 125

9.1 - 12.5

2

level 10

yes

53 - 63

76 - 90

7.6 - 8.9

2

level 9

yes

46 - 52

65 - 75

6.5 - 7.5

2

level 8

yes

36 - 45

51 - 64

5.1 - 6.4

2

level 7

yes

28 - 35

40 - 50

4.0 - 5.0

2

level 6

yes

23 - 27

33 - 39

3.3 - 3.9

2

level 5

yes

18 - 22

26 - 32

2.6 - 3.2

1

level 4

yes

13 - 17

19 - 25

1.9 - 2.5

1

level 3

yes

5 - 12

7 - 18

0.7 - 1.8

1

level 2

yes

< 5

< 7

< 0.7

1

level 1

no

The water softener must be set in
two ways, manually and
electronically.

Setting manually

The appliance is factory set at position 2.
1. Open the appliance door.
2. Remove the lower basket from the

appliance.

3. Turn the water hardness dial to position

1 or 2. Refer to the water hardness
table.

4. Replace the lower basket.

Setting electronically

The appliance is factory set at level 5.
1. Switch on the appliance. Make sure that

the appliance is in setting mode.

2. Press and hold function button (B) and

function button (C) simultaneously until
the indicators of function buttons (A),
(B) and (C) start to flash.

3. Release function button (B) and function

button (C).

4. Press function button (A), the indicators

of function buttons (B) and (C) go off
while the indicator of function button
(A) continues to flash.
• The acoustic signals sound.
• The display shows the current level

(e.g.

displayed and you hear 5

acoustic signals = level 5 ).

5. To change the level, go on pressing

function button (A) until the display
shows the required level. Refer to the
water hardness table.

6. Switch off the appliance to confirm the

operation.

12