Repair instructions

WARNING!
Make sure the recoil spring does
not fly out and cause injury. Wear
eye protection..

7.4 Replacing a worn recoil spring

1

Remove the bolt from the centre of the pulley and

lift off the pulley and spring cassette.

2

Replace the defective spring cassette with a new

one.

3

Fit the bolt through the centre of the pulley and

tighten to a torque of 2–3 Nm. Tension the recoil

spring, see “Tensioning the recoil spring”.

7.5 Starter assembly – refitting

1

Position the starter assembly on the crankcase and

tighten the bolts to a torque of 2.5–3.5 Nm.

7.6 Ignition module – testing

If there is a fault in the ignition system the ignition

module must be tested before the ignition system

is removed.

Test the ignition module as follows:

• Connect a test spark plug 502 71 13-01 to the

ignition lead and clip the test spark plug onto

the cylinder.

• Turn the engine over using the starter cord.
• If the test spark plug produces a spark the

ignition module is OK. (see figure 7)