GAS PIPING

Proper sizing of gas piping depends on the cubic feet per
hour of gas flow required, specific gravity of the gas and the
length of run. National Fuel Gas Code Z223.1 or CAN/CGA
B149.1 or .2 should be followed in all cases unless super-
seded by local codes or gas company requirements. Refer to
Tables 5 and 6.

The heating value of the gas may differ with locality. The
value should be checked with the local gas utility.

NOTE:

There may be a local gas utility requirement specify-
ing a minimum diameter for gas piping. All units
require a 1/2 inch pipe connection at the gas valve.

GAS CONNECTION

The gas supply line can be routed through the hole located
on the left side of the unit. Refer to Figure 7 to locate these
access openings. Typical supply piping arrangements are
shown in Figure 5.

Gas piping recommendations:

1.

A drip leg and a ground joint union must be installed in
the gas piping.

2.

When required by local codes, a manual shut-off valve
may have to be installed outside of the unit.

3.

Use wrought iron or steel pipe for all gas lines. Pipe dope
should be applied sparingly to male threads only.

.

FIGURE 5 - EXTERNAL SUPPLY CONNECTION

EXTERNAL SHUT-OFF

1 / 2 x 1 / 2 G A S C O C K

1 / 2 x 1 / 2 U N I O N

A U T O M A T I C

G A S V A L V E

D R I P L E G

1 / 2 - 1 4 N P T

TABLE 5: NATURAL GAS PIPE SIZING CHART

1

1.

Maximum capacity of pipe in cubic feet of gas per hour (based
upon a pressure drop of 0.3 inch water column and 0.6 specific
gravity gas).

LENGTH

IN FEET

NOMINAL INCHES IRON PIPE SIZE

1/2”

3/4”

1”

1-1/4”

10

132

278

520

1,050

20

92

190

350

730

30

73

152

285

590

40

63

130

245

500

50

56

115

215

440

60

50

105

195

400

70

46

96

180

370

80

43

90

170

350

90

40

84

160

320

100

38

79

150

305

TABLE 6: PROPANE (LP) GAS PIPE SIZING

CHART

1

1.

Maximum capacity of pipe in thousands of BTU per hour (based
upon a pressure drop of 0.5 inch water column).

LENGTH

IN FEET

NOMINAL INCHES IRON PIPE SIZE

1/2”

3/4”

1”

1-1/4”

10

275

567

1,071

2,205

20

189

393

732

1,496

30

152

315

590

1,212

40

129

267

504

1,039

50

114

237

448

913

60

103

217

409

834

70

96

196

378

771

80

89

185

346

724

90

83

173

322

677

100

78

162

307

630