Connection Information

ERX Edge Routers

B-13

GE
single mode

b

GE/FE

GE
I/O
SINGLE
MODE

1 active
1 redundant

SC full duplex

Tx power

min: –11 dBm

max: –3 dBm

Center wavelength: 1300 nm

Rx input power

min: –20 dBm

max: –3 dBm

Rated for 550 m (601 yards)
over 62.5-micron core or
50-micron core MM fiber

Rated for 5 km (3.1 miles)
over 10-micron core cable

HSSI

HSSI-3F

HSSI-3

3

Standard HSSI
connector: 2-row,
50-pin, receptacle
header with rails and
latch blocks

50 feet (15.24 m) maximum
cable length

IPSec Service IPSEC

SERVICE

No I/O
module

N/A

N/A

N/A

OC3 (dual
port)
multimode

OC3

OC3
I/O
MULTI
MODE

2

SC full duplex

Tx power:

min: –19 dBm

max: –14 dBm

Center wavelength: 1310 nm

Rx input power:

min: –30 dBm

max: –14 dBm

Rated for 2 km (1.2 miles)
over 62.5-micron core cable
with an optical loss of 0–9 dB
or 50-micron core cable with
an optical loss of 7 dB

OC3 (dual
port)
single mode

OC3

OC3
I/O
SINGLE
MODE

2

SC full duplex

Tx power:

min: –15 dBm

max: –8 dBm

Center wavelength: 1310 nm

Rx input power:

min: –31 dBm

max: –8 dBm

Rated for 15 km (9.3 miles) of
9-micron core cable

Table B-3 Connection information for module assemblies (continued)

Assembly
Name and
Capability

Line
Module
Label

I/O Module
Label

No. of
Ports

Connector Type

Cabling Specifications

Advertising