APPENDIX B
Module Specifications

B-20

T3 ATM
(3 ports)

T3 ATM

CT3/T3
I/O

3

BNC
75 ohm

The line interface unit
supports two line build-outs:

0–68.5 m (0–225 feet)

69–137 m (226–450 feet)

Signal strength is software
controlled.

The transmitted signal
complies with

ANSI

T1.102-1993: Digital
Hierarchy – Electrical
Interfaces (1999)

for cable

lengths up to 201 m (660
feet).

T3 FRAME
(3 ports)

T3 FRAME

CT3/T3
I/O

3

BNC
75 ohm

The line interface unit
supports two line build-outs:

0–68.5 m (0–225 feet)

69–137 m (226–450 feet)

Signal strength is software
controlled.

The transmitted signal
complies with

ANSI

T1.102-1993: Digital
Hierarchy – Electrical
Interfaces (1999)

for cable

lengths up to 201 m (660
feet).

T3 FRAME
(12 ports)

COCX-F3

CT3/T3
12
I/O

12

BT43 SMB
(cable that adapts to
75-ohm BNC is
available)

The line interface unit
supports two line build-outs:

0–68.5 m (0–225 feet)

69–137 m (226–450 feet)

Signal strength is software
controlled.

The transmitted signal
complies with

ANSI

T1.102-1993: Digital
Hierarchy – Electrical
Interfaces (1999)

for cable

lengths up to 201 m (660
feet).

TSM

TUNNEL
SERVICE

No I/O
module

N/A

N/A

N/A

Table B-3 Connection information for module assemblies (continued)

Assembly
Name and
Capability

Line
Module
Label

I/O Module
Label

No. of
Ports

Connector Type

Cabling Specifications