Understanding Status LEDs

ERX Edge Routers

8-9

Redundancy Status

You can determine the redundancy state of line modules by examining
the online and redundant status LEDs. See

Table 8-5

.

Note: The REDUNDANT LED on the

cOCx/STMx, FE-8, GE/FE, HSSI, OC3 (dual

port), and OCx/STMx

modules is nonfunctional.

LINK LED is not lit

Ethernet connection is
down.

1 Check that Ethernet cables are properly connected to

both the Ethernet port and the appropriate network
device.

2 Contact Juniper Networks Customer Service.

RED ALM

System does not
recognize a port
connection.

Cabling is not connected
properly.

Cable is faulty.

Clocking problem exists.

1 Check that all cables are firmly plugged into OC3

ports and the attached network device.

2 Verify that cables are clean.
3 Test for faulty cables.
4 Verify clock source and configuration.
5 Reset system.

Note: Problem is corrected when normal LED activity is
observed.

YEL ALM
Note: This LED is not
functional on the HSSI line
module.

Far end receive failure
(FERF) exists.

1 Correct FERF problem.
2 Reset system.

Note: Problem is corrected when normal LED activity
is observed.

System will not boot.

Module(s) held offline.

FAIL LED lights

A slot group is overloaded.

1 Issue the show version command to display board

status.

2 Review section on proper slot group configuration in

Chapter 3, Installing ERX Modules

.

3 Reconfigure system with correct slot group

configuration.

4 Reset system.

None

System temperature is
too high.

Vents are blocked.

Fans are not operating.

1 Check your console for a message indicating the

problem. If you have the “system” log set to a severity
of WARNING or higher, a Warning message
indicating the failure is displayed.

2 Issue the show environment command to display

the temperatures. If the temperature is too high,
power down the system.

3 Regulate temperature.
4 Reset system.