System specifications, Appendix a, Appendix a, system specifications – Juniper Networks ERX-1410 User Manual

Page 119: Ls of heat. see, Appendix a, system, Specifications, Specifications (see

Advertising
background image

A

System Specifications

Table A-1 ERX specifications

ERX-1400 Series

ERX-700 Series

Weight
Chassis only
Chassis fully configured

42 lb (18.9 kg)
88 lb (39.6 kg)

22 lb (9.9 kg)
46 lb (20.7 kg)

Dimensions

22.75 (H) x 19 (W) x 16 (D) inches
(57.78 x 48.26 x 40.64 cm)

10.5 (H) x 19 (W) x 16 (D) inches
(26.67 x 48.26 x 40.64 cm)

Environmental Requirements
Ambient operating temperature

Ambient operating humidity

Ambient storage temperature
Ambient storage humidity

(NEBS GR-63-CORE compliant)
Long term: 41

°

to 104

°

F (5

°

to 40

°

C)

Short term: 23

°

to 122

°

F (-5

°

to 50

°

C)

Long term: 5% to 85% (noncondensing)
Short term: 5% to 95% (noncondensing)
–40

°

to 158

°

F (–40

°

to +70

°

C), 95% relative humidity

5% to 95% (noncondensing)

Heat Dissipation

2400 W, 8190 BTU/hour maximum

1400 W, 4780 BTU/hour maximum

Space Requirements

3 feet (90 cm) behind system or
rack

No space requirements for sides of
units or rack

Do not block air vents on front or
back of the system.

3 feet (90 cm) behind system or
rack

Do not block air vents on sides of
the system.

Do not place equipment that
exhausts hot air to right of the
system.

Be aware that system exhausts hot
air from its left side.

Allow at least 18 inches (45 cm) at
side of the unit or rack.

Advertising