CHAPTER 1
ERX System Overview

1-14

Figure 1-10 Data flow when a spare line module is active

For information about installing modules for line module redundancy, see

Chapter 3, Installing ERX Modules

. For information about configuring

and managing SRP module redundancy, see

ERX System Basics

Configuration Guide, Chapter 5, Managing Line Modules and SRP
Modules

, for more information.

Power

The system provides a power architecture that distributes redundant
–48 VDC feeds through the system to each line module, SRP module,
and fan module where DC-to-DC converters provide local conversion to
the required secondary voltages. The system design prevents a failure of
any one of the power components from causing any other component in
the system to fail.

1

2

4

3

Midplane

Redundancy

midplane

Primary

line module

Spare

line module

Redundancy

I/O module

Primary

I/O module

A packet arrives at the primary
I/O module.
The packet passes along the
redundancy midplane from the
primary I/O module to the
redundancy I/O module.
The packet passes from the
redundancy I/O module to the
spare line module.
The spare line module
processes the packet.

1

2

3

4