CHAPTER 3
Installing ERX Modules

3-10

Figure 3-8 Installing an SRP module

9

Insert the module into the backplane by simultaneously depressing
both ejectors (as shown in

Figure 3-7

) and exerting forward pressure

on the module.

10

Tighten the module’s captive screws using a Phillips screwdriver.
Turn both screws several times before tightening them completely to
allow the module to sit correctly.

Installing Line Modules and Their I/O Modules

This section describes the procedures for installing line and I/O modules.

Note: Install the I/O module before you install the corresponding line module;
otherwise, the ERX system diagnostics fail, and after the line module has tried to
reboot, its status will be “inactive” when you issue a
show version command.

ERX-1400

Ejector in open position