Cabling the SRP I/O Module

ERX Edge Routers

4-9

To connect the clock source input ports:

1

Depending on the connector type, complete one of the following
tasks:

E1: Attach the BNC connector to Clock A’s External Timing
port.

T1: Wrap the “Tip” wire on pin marked T of Clock A’s External
Timing port, the “Ground” wire on G pin, and the “Ring” wire
on R pin.

Note: You can use a wire-wrap gun to attach wires to pins.

2

Attach the opposite end of the External Timing cable or wires into
your network’s clock source A.

3

Repeat steps 1 and 2 for the Clock B connections.

Console Ports

There are two ports located in the Console section (as shown in

Figure 4-3

) that allow management access.

The 10/100Base-T Ethernet port accepts an RJ-45 (male)
connector. This port provides an out-of-band connection. (We
ship an Ethernet cable with the system.)

The RS-232 port accepts a DB-9 (female) connector. This port
allows direct CLI access.

Follow this procedure to connect the Console ports. Refer to

Figure 4-3

as

needed.

1

Insert the male RJ-45 connector into the 10/100Base-T port until it
clicks into place.

2

Attach the opposite end of the cable to your appropriate network
device.

3

Insert the female DB-9 connector into the RS-232 port until it is
secure.

4

Hand-tighten the DB-9 connector screws.

5

Attach the opposite end of the cable to your terminal (VT100/ANSI).

See

Chapter 5, Accessing the ERX System

, for more information about

management access.