Chapter 5---Troubleshooting

5-13

Model 330, 340SC, and 370SC Service Manual

Problem and

Symptom to

Check

Possible Solution

Service

Manual

Operator

Manual

Data lost when

projector is
turned off and
back on.

SCB socket batteries weak. “RAM

BATTERY LOW” may appear
on screen.

4.14

“Flagwaving” at top

of picture or top
of image is
skewed.

VCR mode (if using CVID or SVID

input).
Select 2H Sync Enable or
Shift Sync Enable from the
Menu.

5.3

Table 5-4

Convergence and/or

shading is
incorrect after
doing copy
channel.

Menu Position adjustment for the

“Copied to” channel.

Red bands across

image after
channel change.

Channel data not loading properly.

Upgrade software.

Communication

error.

Unplug tethered remote at the

projector
and reconnect.

Check hardwired

cable for broken
wires and/or if
wired for RS-
232 null modem.

Bad RS-232 null modem cable.

Bad RS-232

interface port on
the System
Controller.
Board.

Replace System Controller Board.

4.11

LCD displays

erroneous
characters.

Unplug tethered remote at projector

and reconnect.

Infrared I/R

Remote

No response.

Set I/R remote dip switch settings.

5.8