Chapter 2—Functional Description

Model 330, 340SC and 370SC Service Manual

2-23

I

T Blank

Commanded position of top blanking.

I

B Blank

Commanded position of bottom blanking.

I

/STBP

Command for DC restore timing on either

leading or trailing edge of sync pulse.

I

DC Restore Delay

Commanded timing of DC restore after

reference edge of sync pulse.

I

Internal Sync Forced

Command to force internal sync select.

I

Correction Start Delay

Commanded H phase of correction map.

I

Pincushion Start Delay

Commanded H phase of pincushion, keystone,

and linearity correction.

I

2H Sync Enable

Command determines path of H sync signal.

I

Shifted Sync Enable

Command determines path of H sync signal.

O

/External Sync Detect

Is an external sync available.

O

HCount

Count of H lines per frame.

O

/Phase Lock

Indication of PLL lock.

O

Phase Count

Indication of phase difference between

HSYNC and HFlyback.

Raster Timing Generator I/O

This section provides a description of the inputs to and outputs from the RTG. The I/O
description are arranged by the source/destination of the signal and so the assemblies
communicated with are used as the primary heading of each group of signals and then are
further subdivided into inputs and outputs. In each case, the signal's direction is noted,
with input referring to an input to the RTG, and output to an output from the RTG. (e.g.:
under System Controller Board “Input”; SYSCLK refers to the signal SYSCLK that is an
input to the RTG from the System Controller Board). When test points are provided for
the I/O they are noted.

Table 2-5

Raster Timing Generator I/O Signals

System Controller Board

Inputs

Description

SYSCLK

4 MHz clock signal for derivation of internal HDTV sync signal.

(TP 13)

IICCLK

IIC clock line. Unidirectional clock line for control of

synchronous data transfer over IIC data bus.

Outputs

Description

/IICINT

IIC interrupt line. Signal line for slave boards to inform the SCB

(master) that there is data to be transferred. Master then polls
slaves to determine the source of the interrupt.

/Hx224

Square wave signal 224 X the horizontal frequency for overlay

address generator clocking. (TP 23)