Left to right, Recommended table fabr ication, Aj-66 gas - right to left 14 – Jackson AJ-44 User Manual

Page 22

Advertising
background image

C

Ri

ght Side

34 [864mm]

8

1

2

[217mm]

21 [533mm]

25 [635mm]

12 [307mm]

25 [635mm]

B

Dis

h Clearanc

e

Drive Unit

Left Si

de

66

1

2

[1692mm]

3 [79mm]

1

2

[

15mm]

84 [2134mm]

A

M

L

With Doors

Open

Rear of

M

a

ch

in

e

6 [152mm]

1 [25mm]

Drive Unit

Front View

75

1

2

[1919mm]

62

1

2

[1590mm]

29 [737mm]

6 [152mm]

10 [254mm]

C

A

B

4 [102mm]

7 [178mm]

D

E

8 [203mm]

42 [1067mm]

41 [1041mm]

24 [610mm]

10

1

4

[260mm]

L

24 [610mm]

M

23

1

2

[599mm]

60

1

4

[1530mm]

66

1

4

[1684mm]

F

loor Sink

Or Drain

With 3"

(76 mm)

Minimum Drain Line

25 [635mm]

4 1/2 [114mm]

8

1

4

[210mm]

21 [533mm]

B

A

L

T

able to T

able

Ov

erall

Prewas

h Plan View Sec

tion

wit

h Cold Wat

e

r Thermos

tat

16

3

4

[425mm]

16

1

4

[415mm]

F

G

82 [2086mm]

74 [1883mm]

66 [1679mm]

3/4"

(19 mm)

T

able T

u

rndown

F

lange 3/4"

Max

21"

(533 mm)

Rac

k

Rail Height

Abov

e Dis

htable

1/

4"

(6mm) - 5/

16"

(8mm)

Rac

k

Rail

Tu

b

T

able

Us

e Silic

one Sealer

Between T

able and

Lip of Mac

h

ine to

Prev

ent Leak

age

Recommended Table Fabr

ication

Not

e

: Tub Will A

c

c

ept

a T

able F

lange

Up to 24 7/8"

(632 mm)

4"

(102 mm) wide x

16"

(406 mm)

long c

u

tout in Vent Cowl/Splas

h

Shield. Shipped with Cov

e

r Plate.

22 [559mm]

44 [1121mm]

B

a

s

e

Unit

P

rewas

h

Left to Right

Legend

A - Mac

h

ine water inlet 3/4"

NPT

, 180°F

Hi-temp,140°

F

Low-temp minimum

B - Elec

tric

al c

onnec

tion

C - Drain c

onnec

tion 1-1/2"

NPT

D - Vent c

o

llar - Optional

E - Vent c

o

wl s

tandard

F

- 3/4"

NPT

180°

F

Water Inlet for was

h

tank

f

ill,

f

inal rins

e,

& t

ank

heat

ing.

From gas

boos

ter heater. Interc

onnec

ting hos

e

prov

ided by

manufac

turer.

G - 3/4"

NPT

140°

F

Water inlet for

gas

boos

ter heater.

H - 3/4"

NPT

180°

F

Water Outlet

c

onnec

tion to line on dis

h

mac

h

ine.

Connec

tion hos

e prov

ided by

manufac

turer.

J

- 3/4"

NPT

Gas

Connec

tion

K - 4"

OD Vent pipe c

onnec

tion. F

lue to

be ins

talled to meet loc

a

l c

odes

by

ins

talling c

ontrac

tor.

L - Prewas

h water inlet 3/4"

NPT

110°

F

-140°F

M - Cold water thermos

tat plumbing

c

onnec

tion 3/4"

NPT

- Optional

Not

e

: A

ll v

e

rt

ic

al dimens

ions

are +/- 1/2"

from

floor due to adjus

table bullet feet.

6 [152mm]

30 [763mm]

14 [357mm]

7

1

4

[185mm]

1

1

4

[

35mm]

K

J

H

G

K

J

H

G

8

3

4

[222mm]

11

3

4

[298mm]

14

3

4

[375mm]

20

3

4

[527mm]

36 [914mm]

26

1

2

[672mm]

31

1

4

[794mm]

6

1

2

[163mm]

16 [407mm]

AJ-44C Series Technical Manual 7610-001-76-22

Issued: 03-21-2006 Revised: 09-29-2007

SECTION 1: SPECIFICATION INFORMATION

AJ-66 GAS - RIGHT TO LEFT

14

Advertising