Right to left, Ri ght s ide, Le ft s ide – Jackson AJ-44 User Manual

Page 24: Fr ont v ie w, Reco mmen d ed table fabricatio n, Aj-66 steam - right to left 16

Advertising
background image

C

Ri

ght S

ide

34 [864mm]

8

1

2

[217mm]

21 [533mm]

25 [635mm]

12 [307mm]

25 [635mm]

B

Di

sh Clear

ance

Driv

e

Unit

Le

ft S

ide

66

1

2

[1692mm]

3 [79mm]

1

2

[15mm]

84 [2134mm]

A

G

F

Wi

th Door

s Open

Rear of

Machi

n

e

6 [152mm]

Right to Left

Legend

A -

Machi

ne water

inl

e

t 3/4"

NPT

, 180°

F

Hi-

temp,140°F

Low-temp mi

ni

mum

B -

El

ectri

c

al

connecti

on

C -

Dr

ai

n connecti

on 1-

1/2"

NPT

D - Vent col

lar - Opti

onal

E -

Vent cowl standar

d

F - Pr

ewash water inlet 3/4"

NPT

110°

F-

140°

F

G - Cold water

thermostat pl

umbi

ng

c

onnec

ti

on

3/4" N

P

T

- O

p

ti

onal

H

- Steam el

ec

tri

c

al

c

onnec

ti

on

J

- 1" N

P

T

St

eam

c

onnec

ti

on

K

- 3/

4" C

ondens

ate c

onnec

ti

on

L

- 3/4"

N

P

T

Inc

o

mi

ng 110°F

w

a

ter

c

onnec

ti

on

M

- 3/4"

N

P

T

180°F

w

a

te

r to di

s

h

mac

h

ine.

Note: Al

l verti

c

al

di

mensi

ons ar

e +/- 1/2"

fr

om floor due to adj

ustabl

e bul

le

t feet.

1 [25mm]

Driv

e

Unit

Fr

ont V

ie

w

75

1

2

[1919mm]

62

1

2

[1590mm]

29 [737mm]

6 [152mm]

10 [254mm]

C

A

B

4 [102mm]

7 [178mm]

D

E

8 [203mm]

42 [1067mm]

41 [1041mm]

24 [610mm]

10

1

4

[260mm]

F

24 [610mm]

G

23

1

2

[599mm]

60

1

4

[1530mm]

66

1

4

[1684mm]

Fl

oor Si

nk Or Dr

ai

n

Wi

th 3"

(76 mm)

Minimum Dr

ai

n Li

ne

25 [635mm]

4 1/2 [114mm]

8

1

4

[210mm]

21 [533mm]

B

A

F

Tabl

e to T

abl

e

Over

al

l

Pr

ewash Plan Vi

ew Secti

o

n

wi

th Col

d

Water Ther

mostat

16

3

4

[425mm]

16

1

4

[415mm]

F

G

82 [2086mm]

74 [1883mm]

66 [1679mm]

3/4"

(

19 mm)

Tabl

e Turndown

Fl

ange 3/4"

Max

21"

(533 mm)

Rack Rai

l Hei

ght

Above Di

shtabl

e

1/4"

(

6

mm)

-

5/16"

(

8

mm)

Rack Rai

l

Tu

b

Tabl

e

Use Si

licone Seal

er

Between Tabl

e and

Li

p of Machi

ne to

Pr

event Leakage

Reco

mmen

d

ed Table Fabricatio

n

Note: Tub Wi

ll Accept

a Tabl

e Fl

ange

Up to 24 7/8"

(632 mm)

4"

(

102 mm) wi

de x 16"

(

406 mm)

long cutout in Vent Cowl

/Spl

ash

Shi

e

ld

. Shi

pped wi

th Cover

Pl

ate.

22 [559mm]

44 [1121mm]

Base Uni

t

Pr

ewash

12

1

2

[316mm]

F

H

J

L

M

K

L

H

J

M

F

38 [966mm]

11

1

4

[285mm]

13

1

2

[345mm]

23

3

4

[604mm]

4

1

4

[110mm]

5

3

4

[148mm]

8

1

2

[218mm]

6

1

4

[159mm]

43 [1092mm]

17

1

2

[445mm]

6

1

2

[162mm]

11

1

2

[295mm]

15

3

4

[400mm]

16

1

2

[417mm]

G

27 [686mm]

AJ-44C Series Technical Manual 7610-001-76-22

Issued: 03-21-2006 Revised: 09-29-2007

SECTION 1: SPECIFICATION INFORMATION

AJ-66 STEAM - RIGHT TO LEFT

16