Sterling Power Products DAI-1500C-24xx User Manual

Page 12

Advertising
background image

-

9-

D.3 Cabling / wiring
When making connections to the unit you must ensure that all connections

are carried out in a clean and correct manner and under no circumstances that a
cable is connected to a wrong terminal.
Connecting the unit must be carried out in the following order.

D.3.

1 Connection to battery

Prepare the batteries for connection. Prepare battery cables, if necessary press

on cable tabs/shoes. Connect the red cable to the Battery positive fuse/circuit
breaker and the black cable to battery Minus (-) Take care when connecting the
second cable to the battery, as a spark is produced, this is caused for a short time
due to high current flowing in the unit to charge the capacitors. This is another
reason to install a battery fuse/circuit breaker. For this reason follow strictly the
safety measures described in this manual.

DO NOT INSERT THE BATTERY FUSE AT THIS STAGE.


D.3.

2 Connection to the AC OUTPUT.

The AC output must be connected to the screw terminal AC OUTPUT. For this,

use a 3-core cable with a conductor cross section of 2,5mm². Connections are
marked as follows “OUT / N”=Neutral, “GND”=Earth, “OUT / L”=Live or Active.


Caution: High voltage can be at the AC output, ensure the unit is not

connected when making AC connections.


D.3.

3 Connection to the AC INPUT

The AC input supply from the electricity grid or from a generator must be
connected to the screw terminals AC INPUT. For this use a 3-core cable with a
conductor cross section of 2,5mm². Connections are marked as follows
“IN / N”=Neutral, “GND”=Earth, “IN / L”=Live or Active.

Advertising
This manual is related to the following products: