4. SELF-DIAGNOSTICS

PROCEDURE

After turning on power to the air conditioner, use the remote

controller and follow the steps below to execute self-

diagnostics.

Step 1: Press and hold the remote controller NIGHT SET

BACK (NSB) button and 1 HR TIMER button. Then,

press and hold the ACL (reset) button with a pointed

object such as the tip of a pen. After 5 seconds,

release ACL button first, then release NIGHT SET

BACK (NSB) and 1 HR TIMER buttons, "oP-1" (test

run) appears, blinking in the remote controller clock

display area.

Step 2: Next, press the 1 HR TIMER button once to change

the display from "oP-1" to "oP-3" (self-diagnostics).

(The display continues to blink.)

Step 3: Finally press the ON/OFF button to engage self-

diagnostics mode.

• The self-diagnostics function utilizes the 3 indicator lamps

on the main unit, in combinations of ON lamps, blinking

lamps, and OFF lamps, to report the existence of sensor

trouble or a protective operation. (The lamps blink or

remain ON for 5 seconds, then turn OFF for 2 seconds.)

Self-diagnostics is completed when the buzzer sounds 3

short beeps.

• A maximum of 3 self-diagnostics reports are displayed, for

5 seconds each, beginning with the most recent report.

Following this display the lamps turn OFF. In order to view

the self-diagnostics results again, press the ON/OFF button

again.

• The 3 lamps remain OFF if no trouble has occurred.

<IMPORTANT> After self-diagnostics is completed, be sure

to press the ACL (reset) button to return to

normal mode. The air conditioner will not

operate if this is not done.