Usb clock configuration, Section – Silicon Laboratories C8051F347 User Manual

Page 166

Advertising
background image

C8051F340/1/2/3/4/5/6/7/8/9/A/B/C/D

166

Rev. 1.3

16.4. USB Clock Configuration

USB0 is capable of communication as a Full or Low Speed USB function. Communication speed is
selected via the SPEED bit in SFR USB0XCN. When operating as a Low Speed function, the USB0 clock
must be 6 MHz. When operating as a Full Speed function, the USB0 clock must be 48 MHz. Clock options
are described in

Section “14. Oscillators” on page 131

. The USB0 clock is selected via SFR CLKSEL

(see SFR Definition 14.6).

Clock Recovery circuitry uses the incoming USB data stream to adjust the internal oscillator; this allows
the internal oscillator (and 4x Clock Multiplier) to meet the requirements for USB clock tolerance. Clock
Recovery should be used in the following configurations:

When operating USB0 as a Low Speed function with Clock Recovery, software must write ‘1’ to the
CRLOW bit to enable Low Speed Clock Recovery. Clock Recovery is typically not necessary in Low Speed
mode.

Single Step Mode can be used to help the Clock Recovery circuitry to lock when high noise levels are pres-
ent on the USB network. This mode is not required (or recommended) in typical USB environments.

USB Register Definition 16.5. CLKREC: Clock Recovery Control

Communication Speed

USB Clock

4x Clock Multiplier Input

Full Speed

4x Clock Multiplier

Internal Oscillator

Low Speed

Internal Oscillator / 2

N/A

Bit7:

CRE: Clock Recovery Enable.
This bit enables/disables the USB clock recovery feature.
0: Clock recovery disabled.
1: Clock recovery enabled.

Bit6:

CRSSEN: Clock Recovery Single Step.
This bit forces the oscillator calibration into ‘single-step’ mode during clock recovery.
0: Normal calibration mode.
1: Single step mode.

Bit5:

CRLOW: Low Speed Clock Recovery Mode.
This bit must be set to ‘1’ if clock recovery is used when operating as a Low Speed USB
device.
0: Full Speed Mode.
1: Low Speed Mode.

Bits4–0: Reserved. Read = Variable. Must Write = 01001b.

Note:

The USB transceiver must be enabled before enabling Clock Recovery.

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

Reset Value

CRE

CRSSEN

CRLOW

Reserved

00001001

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

USB Address:

0x0F

Advertising