16-bit pulse width modulator mode, Figure 22.9. pca 16-bit pwm mode, Bit pulse width modulator mode – Silicon Laboratories C8051F347 User Manual

Page 263

Advertising
background image

Rev. 1.3

263

C8051F340/1/2/3/4/5/6/7/8/9/A/B/C/D

22.2.6. 16-Bit Pulse Width Modulator Mode

A PCA module may also be operated in 16-Bit PWM mode. In this mode, the 16-bit capture/compare mod-
ule defines the number of PCA clocks for the low time of the PWM signal. When the PCA counter matches
the module contents, the output on CEXn is asserted high; when the counter overflows, CEXn is asserted
low. To output a varying duty cycle, new value writes should be synchronized with PCA CCFn match inter-
rupts. 16-Bit PWM Mode is enabled by setting the ECOMn, PWMn, and PWM16n bits in the PCA0CPMn
register. For a varying duty cycle, match interrupts should be enabled (ECCFn = 1 AND MATn = 1) to help
synchronize the capture/compare register writes. The duty cycle for 16-Bit PWM Mode is given by
Equation 22.3.

Important Note About Capture/Compare Registers

: When writing a 16-bit value to the PCA0 Capture/

Compare registers, the low byte should always be written first. Writing to PCA0CPLn clears the ECOMn bit
to ‘0’; writing to PCA0CPHn sets ECOMn to ‘1’.

Equation 22.3. 16-Bit PWM Duty Cycle

Using Equation 22.3, the largest duty cycle is 100% (PCA0CPn = 0), and the smallest duty cycle is
0.0015% (PCA0CPn = 0xFFFF). A 0% duty cycle may be generated by clearing the ECOMn bit to ‘0’.

Figure 22.9. PCA 16-Bit PWM Mode

DutyCycle

65536

PCA0CPn

65536

-----------------------------------------------------

=

PCA0CPLn

PCA0CPHn

Enable

PCA Timebase

0 0 x 0

x

PCA0CPMn

P

W

M

1
6
n

E
C

O
M

n

E
C
C
F
n

T

O
G

n

P

W

M

n

C
A
P
P

n

C
A
P
N

n

M

A
T

n

1

16-bit Comparator

CEXn

Crossbar

Port I/O

Overflow

Q

Q

SET

CLR

S

R

match

PCA0H

PCA0L

ENB

ENB

0

1

Write to

PCA0CPLn

Write to

PCA0CPHn

Reset

Advertising
This manual is related to the following products: