Maintenance, Lubrication, Care of your dryer – Speed Queen HVR-M15N/M15P User Manual

Page 11: Motor overload protector

Advertising
background image

-11-

513218

© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT

Maintenance

Lubrication

All moving parts are sealed in a permanent supply
of lubricant or are equipped with oilless bearings.
Additional lubrication will not be necessary.

Care of Your Dryer

Dryer Interior

Wipe the surfaces using a soft cloth and household
cleaner or a non-abrasive paste of powdered
laundry detergent and hot water, followed by a
short heat cycle with a load of rags.

To remove crayon or ball point ink off the dryer
drum, put the heat on high and use old rags in the
dryer to absorb the crayon or ink. If unsuccessful,
contact the appliance dealer. DO NOT use any
chemicals in the dryer.

IMPORTANT: The use of chlorine bleach for
removing any discolorations should be avoided
because bleach could damage the finish.

Cabinet

Wipe the dryer cabinet as needed. If detergent,
bleach or other washing products have been spilled
on the dryer, wipe immediately. Some products will
cause permanent damage if spilled on the cabinet.

Control Panel

Use only a damp or sudsy cloth for cleaning the
control panel. Some spray pretreat products may
harm the finish on the control panel.

NOTE: The wiring diagram is located inside the
control panel.

Exhaust System

The exhaust duct should be inspected after one
year of use and cleaned if necessary by a qualified
service person.The exhaust duct should be
inspected and cleaned every one to two years as
required thereafter. Every two years a qualified
service person should remove all front panels and
vacuum the inside of the dryer.

NOTE: This recommended maintenance is not
covered under the terms of the warranty.

The weather hood should be checked frequently to
make sure the dampers move freely, dampers are
not pushed in and that nothing has been set
against them.

Keep dryer area clear and free from combustible
materials, gasoline and other flammable vapors and
liquids.

Do not obstruct the flow of combustion and
ventilation air.

NOTE: Verify proper operation after servicing.

Motor Overload Protector

The dryer’s motor overload protector stops the
motor automatically in the event of an overload.
After cooling, the overload protector will reset
itself. Dryer can be restarted by pushing the timer
knob in. If overload protector cycles again, remove
the dryer from use and call the service person to
correct the problem.

To reduce the risk of an electric shock,

serious injury or death, disconnect the

electrical service to the dryer before

cleaning the interior.

W132

WA R N I N G

To reduce the risk of electric shock,

disconnect the electrical service to the

dryer before cleaning.

W043

WA R N I N G

Advertising