OHMMETER CONNECTIONS

O H M M E T E R R E A D I N G

“Plus” Lead

“Minus” Lead

Collector

Emitter

Collector

Emitter
Base

Base

Emitter

Collector

Base
Base

Collector

Emitter

N.P.N. Transistor P.N.P. Transistor

High
High
High
High
L o w
L o w

High
High
L o w
L o w
High
High

With the ohmmeter “plus” probe on the anode end of a

d i o d e , a n d t h e “ m i n u s ”

p r o b e o n t h e c a t h o d e e n d , t h e

ohmmeter should read approximately 2000 ohms or less. With

the meter probes reversed, a reading of about 10,000 ohms or

more should occur. If either of these conditions is not met, the
diode should be replaced.

Power Drain Resistor (R

SEL

):

The following condition may occur after replacement of

d r i v e r t r a n s i s t o r s Q 3 3 a n d Q 3 4 , o u t p u t t r a n s i s t o r s Q 3 5
through Q38, or diodes D6 and D7. If the unit appears to

o p e r a t e a t a n e x c e s s i v e l y h i g h t e m p e r a t u r e o r t h e r m a l l y
recycles after about 10 minutes with no signal input, the

“cold” standby power drain may be excessive (up to 20 watts
higher than normal; a higher power drain indicates further

circuitry problems). The nominal power drain under these

conditions should be 60 watts; if the measured figure exceeds
75 watts, insert a resistor (R

S E L

) in parallel with the 56-ohm

resistor between the base of transistor Q33 and the junction of
diodes D6 and D8 (figure 17, page 21). R

S E L

( ½ W , 1 0 % )

should be either 180 ohms to decrease the power consumption
by 20 watts, or 82 ohms to decrease the power consumption
by 30 watts.

Lamp Replacement:

The two lamps I2 and I3, Figure 12, Page 14 which provide

illumination of the front panel controls are 115 to 125 volt,

15 watt incandescent bulbs. These bulbs are soldered and

epoxied into the molded plastic sockets in order to meet

Underwriters’ Laboratories requirements. The assembly may
be removed by unsoldering the lamp leads at the terminal

strips and removing the screw that holds the socket to the
chassis.

Reverberation Assembly:

The Reverberation Assembly M3, Figure 13, Page 15 may

be removed and returned to the factory Service Department

for repair if a malfunction should occur. The amplifier can be

operated without this assembly. To eliminate possible damage,

or shock hazard, the plug-in cables should be temporarily
inserted in the nylon inserts normally used to mount this

sub-assembly. If extensive damage has occurred, a replacement

Reverberation Assembly may be ordered through the dealer or

from the factory Service Department.

Replacement Parts:

Parts that are readily available through local electronic parts

distributors are not shown on the accompanying Parts List.
Their values are shown on the circuit diagram. The special
custom made parts are shown on the Parts List.

The commercial alternates shown on the Parts List are not

necessarily equivalents, but may be used in the even that direct

f a c t o r y r e p l a c e m e n t s a r e n o t i m m e d i a t e l y a v a i l a b l e . T o

maintain the highest possible performance and reliability,

S h u r e f a c t o r y r e p l a c e m e n t p a r t s s h o u l d b e u s e d . W h e n
ordering replacement parts, specify the Shure Replacement Kit

N u m b e r , d e s c r i p t i o n , p r o d u c t m o d e l n u m b e r a n d s e r i a l

number.

EQUIPMENT DESIGNED FOR USE

WITH THE VA300 VOCAL MASTER

VA300-S
VA301-S

PM300
A3PC

A3PC-C

A3PC-S

A31PC-S

A3S-C

ASS-S
A 5 0 X C

A3S-T
A95 Series

Vocal Master Speaker Column
Vocal Master Monitor Speaker

Power Master Booster Amplifier

Soft Cover Set
Console Soft Cover

Speaker Column Soft Cover

Monitor Speaker Soft Cover

Fold-Up Console Stand

Speaker Stand

15m (50 ft) Speaker Extension Cable

Speaker Stand

Low Impedance Transformers

GUARANTEE: This Shure product is guaranteed in normal use to
be free from electrical and mechanical defects for a period of one

year from the date of purchase. Please retain proof of purchase

date. This guarantee includes all parts and labor.

SHIPPING INSTRUCTIONS: Carefully repack the unit and return it

prepaid to the factory. If outside the United States, return the unit

to your authorized Shure Service Center for repair. The unit will be

returned to you prepaid.

SERVICE: If information or service should be required, contact
your local Shure Vocal Master dealer explaining your difficulty in

detail. In addition, the Shure factory service department will be
ready to assist you immediately upon request.