Maintenance, 6) components substitution, Denominations w – Smeg SE32CX User Manual

Page 10

Advertising
background image

22

MAINTENANCE

Before doing any action, disconnect the

appliance from the input power.

6) COMPONENTS SUBSTITUTION

To replace the components lodged in the internal

part, is necessary to take the appliance up from

the furniture, overturn it, loosen the screws and

take away the bottom.

After these actions is possible to work on the

plates, commutators, clamps and input cable.

In case of substitution of the input cable, the

installer must keep the "earth" conductor

longer than "live" ones, and must respect the

cautions in paragraph "ELECTRICAL

CONNECTION".

To reassemble the appliance repeat the inverse

process.

7) TECHNICAL CHARACTERISTICS OF

THE ELECTRICAL COMPONENTS

To facilitate the job of the installer we present a

scheme with the characteristics of the

components.

Denominations

W

Radiant electric heating element Ø 145 mm

1200

Radiant electric heating element Ø 180 mm

1700

POWER OF ELECTRICAL COMPONENTS

TYPE AND SECTION OF THE POWER CABLES

(for 2 or 1 HEATING ELEMENTS)

(*) keeping in mind the contemporaneousness factor

3 X 1.5 mm

2

(*)

Cable type

Single phase power

230 - 240 V ~

Rubber

H05 RR-F

Advertising