Installation, 5) electrical connection – Smeg SE32CX User Manual

Page 9

Advertising
background image

21

INSTALLATION

5) ELECTRICAL CONNECTION

The electrical connection has to be done in

accordance with all electrical and installation

requirements of the regulation.

Before proceeding with the connection, please,

verify that:

- the power of the electrical system and the power

of the outlets is adequate to the maximum power

of the appliance (see the identification label in the

lower part of the body).

- The outelets and all the electrical system has an

efficient connection to the "earth" according with

the Regulation. We disclaim all responsabilities

for not observing such points.

- If the appliance is not equipped with an input

cable, connect to the clump with an adequate

section cable (see scheme paragraph 7) keeping

the "earth" conductor longer than "live" ones,

following the scheme of fig. 9.

When the connection to the input system has

been done through a outlet:

- apply to the input cable "C", if unprovided, a

normalized plug adequate to the load indicated in

the identification label. Connect the cables

according to the scheme of fig. 9, making sure to

respect the undermentioned respondences:

Letter L (Live) = cable brown colour;

Letter N (Neutral) = cable blue colour;
Earth symbol

= green - yellow wire.

- The input cable has to be located so that never

reach the over temperature of 75K.

- Please do not use in the connection any

reduction, adaptation that may provoke a false

contact with following dangerous overheatings.

- The outlet must be accessible after the built-in.

When the connection has been done directly to

the input system:

- interpose between the appliance and the system

an onnipolar switch, adequate to the load of the

appliance, with a minimum nose between the

contacts of 3 mm.

- Keep in mind that the " earth " cable does not

have to be interrupted by the switch.

- In an alternative solution the electrical connection

can also be protected by a differential switch with

high sensitivity.

We recommend to fix the earth coloured cable to

an appropriate earth installation.

WARNINGS:

all our products are projected and built

according with the European Norms

EN 60 335-1, EN 60 335-2-6 and relative

amendments.

The appliance has been produced

according with the European Directives:

- CEE 2004/108/CE concerning the

compatibility electromagnetic.

- CEE 2006/95 concerning the electrical

security.

FIG. 9

FIG. 10

Advertising