Rough-in dimensions – State Industries PCE 6-120 User Manual

Page 2

Advertising
background image

2

ROUGH-IN DIMENSIONS

RECOVERY CAPACITIES

Element

U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED

Wattage

INPUT

36F°

40F°

54F°

60F°

72F°

80F°

90F°

100F° 108F° 120F° 126F°

(Upper/Lower)

KW

20C°

22.2C°

30C°

33.3C°

40C°

44.4C°

50C°

55.5C° 60C° 66.6C° 70C°

NON-SIMULATANEOUS OPERATION

/1500

GPH

17

15

11

10

8

8

7

6

6

5

5

1.5

LPH

64

58

43

38

32

29

26

23

21

19

18

/2000

GPH

23

20

15

14

11

10

9

8

8

7

6

2.0

LPH

85

77

57

51

43

38

34

31

28

26

24

/2500

GPH

28

25

19

17

14

13

11

10

9

8

8

2.5

LPH

107

96

71

64

53

48

43

38

36

32

30

3000/3000

GPH

34

30

23

20

17

15

14

12

11

10

10

3.0

LPH

128

115

85

77

64

58

51

46

43

38

37

4000/4000

GPH

45

41

30

27

23

20

18

16

15

14

13

4.0

LPH

170

153

114

102

85

77

68

61

57

51

49

4500/4500

GPH

51

46

34

30

25

23

20

18

17

15

14

4.5

LPH

192

173

128

115

96

86

77

69

64

58

55

5000/5000

GPH

56

51

38

34

28

25

23

20

19

17

16

5.0

LPH

213

192

142

128

107

96

85

77

71

64

61

6000/6000

GPH

68

61

45

41

34

30

27

24

23

20

19

6.0

LPH

256

230

170

153

128

115

102

92

85

77

73

SIMULATANEOUS OPERATION

3000/3000

GPH

68

61

45

41

34

30

27

24

23

20

19

6

LPH

256

230

170

153

128

115

102

92

85

77

73

4000/4000

GPH

90

81

60

54

45

41

36

32

30

27

26

8

LPH

341

307

227

205

170

153

136

123

114

102

97

4500/4500

GPH

101

91

68

61

51

46

41

36

34

30

29

9

LPH

384

345

256

230

192

173

153

138

128

115

110

5000/5000

GPH

113

101

75

68

56

51

45

41

38

34

32

10

LPH

426

384

284

256

213

192

170

153

142

128

122

6000/6000

GPH

135

122

90

81

68

61

54

49

45

41

39

12

LPH

511

460

341

307

256

230

205

184

170

153

146

Recovery capacities at 100° F rise equal: for non-simultaneous element operation = 4.1 gal. x KW of one element; for simultaneous element operation
= 4.1 gal. x 2/3 KW of both elements. For other rises multiply element KW as previously explained by 410 and divide by temperature rise. Full load current for single phase
= total watts : voltage.

ROUGH-IN DIMENSIONS

Approx.

Models

No. of Tank Capacity

A

B

C

D Shipping Weight.

Dimensions

Elements

US Gals.

Litres

inches

mm

inches

mm

inches

mm

inches

mm

Lbs.

Kg.

PCE 6 1OMSA

1

6

23

15 1/2

394

14 1/4

362

11

279

-

-

35

15.9

PCE 10 1OMSA

1

10

38

18 1/4

464

18

457

12 1/2

318

-

-

54

24.5

PCE 17 OMSA

1

15

57

26

660

18

457

20 1/2

521

-

-

58

26.3

PCE 20 1OMSA

1

20

76

22 1/4

565

21 3/4

552

15 3/8

391

-

-

73

33.1

PCE 30 2OLSA

2

30

114

30 7/8

784

21 3/4

552

24 1/8

613

8

203

100

45.4

PCE 40 2OLSA

2

40

151

32 1/4

819

24

610

25 9/16

649

8

203

125

56.7

PCE 50 2OLSA

2

50

189

32 1/4

819

26 1/2

673

25 1/8

638

8

203

166

75.3

PCE 30 2ORTA

2

30

114

34 1/2

876

20 1/2

521

-

-

8

203

98

44.5

PCE 40 2ORTA

2

40

151

45 1/8

1146

20 1/2

521

-

-

8

203

113

51.3

PCE 52 2ORTA

2

50

189

54 7/8

1394

20 1/2

521

-

-

8

203

131

59.4

PCE 66 2ORTA

2

66

250

60 3/4

1543

21 3/4

552

-

-

8

203

176

79.8

PCE 82 2ORTA

2

80

303

59 3/8

1508

24

610

-

-

8

203

211

95.7

PCE 120 2ORTA

2

119

450

62 7/16

1586

29 3/8

746

-

-

8

203

326

147.9

* NO SIDE OUTLET AVAILABLE