Wiring diagrams – State Industries PCE 6-120 User Manual

Page 5

Advertising
background image

5

WIRING DIAGRAMS

C-2 CIRCUIT

FOR SINGLE

ELEMENT HEATERS

EQUIPPED WITH HIGH

LIMIT CONTROL

Size Temperature Rating of Conductor
See Table 310-13 in Code

AMG

60° C

75° C

MCM

(140° F)

(167° F)

TYPES:

TYPES:

RUW

RH, RHW, RUH,

(14-2),

(14-2), THW

T, TW,

THWN, XHHW,

UF

USE

18

- - -

- - -

16

- - -

- - -

14

15

15

12

20

20

10

30

30

8

40

45

6

55

65

4

70

85

3

80

100

Size Temperature Rating of Conductor

See Table 310-13 in Code

AMG

60° C

75° C

MCM

(140° F)

(167° F)

TYPES:

TYPES:

RUW

RH, RHW, RUH,

(12-2),

(12-2), THW

T, TW,

THWN, XHHW,

UF

USE

12

15

15

10

25

25

8

30

40

6

40

50

4

55

65

3

65

75

2

75

90

1

85

100

FACTORY WIRED

---------- FIELD WIRING
WHITE FOR 120V
AND 277V

Portion of Table 310-18 follows:
Allowable Ampacities of Insulated Aluminum and Copper -Clad Aluminum Conductors.

Not more than three conductors in Raceway or Cable or Direct Burial (Based on Ambient Temperature of 30° C, 86° F. These
ampacities relate only to conductors described in Table 310-13 in Code.

For ambient temperatures over 30° C (86° F), see Correction Factors, Note 13 in Code.

A-8 CIRCUIT FOR DUAL ELEMENT HEATER

Advertising