Control instructions, Manual timer control, Manual timer control rt control suffix – Speed Queen Drying Tumblers TMB1268C User Manual

Page 25

Advertising
background image

© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

Installation/Operation Supplement

23

M414881 (EN)

Control Instructions

Manual Timer Control

RT Control Suffix

1. Set the HEAT/DRYING timer for the number of

minutes (from 0-60) desired.

2. Set the COOL DOWN/COOLING timer for the

number of minutes (from 0-15) desired.

3. Set the TEMPERATURE selector at HIGH,

LOW or anywhere between these settings.

4. Press the PUSH TO START button in, and hold it

in for approximately three seconds. This starts
the tumbler cycle.

IMPORTANT: If the loading door or lint panel
door is opened during the cycle, the heating system
will shut off and the motor will stop. To restart the
cycle, both doors must be closed and the PUSH TO
START button must be pressed in.

5. When the cycle is complete, open door and

remove the laundry.

TMB2142N

Figure 6

TMB2143N

Figure 7

TMB2144N

Figure 8

10

20

40

30

50

60

0

HEAT

10

5

COOL

DOWN

15

0

HIGH

TEMPERATURE

LOW

TMB2146N

Figure 9

PUSH

TO

START

Advertising