Ignition Control Operation

Diagnostic LED (DGN LED)

/ Error Codes

The Diagnostic LED or DGN LED is located by the
power connector on the ignition control. Refer to
Figure 24. The Diagnostic LED will indicate the status
of the ignition control. Refer to Table 5.

The Diagnostic LED will flash error codes one half
second on and one half second off. Error codes are
separated by a one second pause before the code is
repeated.

LED Color

Description

Orange-Yellow

Initialization

Green

Standby / Normal Operation

Red

Fault Indication Code

Table 5

Error

Code

DGN LED status

Fault Type

1

Red

Ignition Control Internal Failure

2

2 Red Flashes

Gas Valve Not Connected

3

3 Red Flashes

Ignition/Flame Sense Failure

4

4 Red Flashes

Reset Switch is Shorted

5

Slow Red and Green Flashes

Low Voltage Detection

6

Fast Red and Orange Flashes

Ignition Control is in Reset Delay

TMB2176N

1

Diagnostic (DGN) LED

Figure 24

1