Pin No.

Pin Name

I/O

Description

35

DSPLAT

O

Serial data latch pulse output to the CXD2726Q (IC100)

36

DSPRST

O

Reset signal output to the CXD2726Q (IC100) “L”: reset

37

NC

O

Not used (open)

38

DVCC

Power supply terminal (+5V) (for D/A converter)

39

DVSS

Ground terminal (for D/A converter)

40, 41

NC

O

Not used (open)

42

AVCC

Power supply terminal (+5V) (for analog system)

43

AVRH

I

Reference voltage (+5V) input terminal (for A/D converter)

44

AVRL

I

Reference voltage (0V) input terminal (for A/D converter)

45

AVSS

Ground terminal (for analog system)

46

KEYIN0

I

Key input terminal (A/D input) (LSW901 to LSW908, S901 to S904)
OFF, SOURCE, SOUND EQ, MENU, PTY DSPL, LIST, ENTER, o MODE, SEEK/AMS -
. m + > M, DISC/PRST +, DISC/PRST – keys input

47

KEYIN1

I

Key input terminal (A/D input) (LSW801, LSW909 to LSW917)
Z, DSO, TA, AF, 6 to 3 SHUF 2, REP 1 keys input

48

RCIN0

I

Rotary remote commander key input terminal (A/D input)

49

DSTSEL

I

Destination setting terminal (A/D input) “L”: XR-C7500R/C7500RX: TYPE A,
“M”: XR-C7500R/C7500RX: TYPE C, “H”: XR-C7500R/C7500RX: TYPE B

50

QUALITY

I

Noise level detection signal input at SEEK mode (A/D input)

51

FMAGC

I

FM AGC detection signal input from the FM/AM tuner unit (TUX1) (A/D input)

52

MPTH

I

Multi-path detection signal input from the RDS decoder (IC50) (A/D input)

53

VSM

I

FM and AM signal meter voltage detection input from the FM/AM tuner unit (TUX1) (A/D input)

54

VCC

Power supply terminal (+5V)

55

AMP ON

O

Standby on/off control signal output to the power amplifier (IC700)
“L”: standby mode, “H”: amp on

56

NS-MASK

O

Discharge control signal output for the noise detection circuit “H”: discharge

57

MTLOUT

O

METAL on/off control signal output to the CXA2510AQ (IC250) “H”: METAL on

58

REEL

I

Rotation detect signal input from supply reel sensor and take-up reel sensor on the deck
mechanism

59

LM-EJ

O

Motor drive signal output to the loading/tape operation motor drive (IC201) “H” active
(For the eject direction and reverse side operation) *1

60

LM-LOD

O

Motor drive signal output to the loading/tape operation motor drive (IC201) “H” active
(For the loading direction and forward side operation) *1

61

CM ON

O

Capstan/reel motor (M901) drive signal output terminal “H”: motor on

62

TAPE ON

O

Tape system power supply on/off control signal output terminal “H”: tape on

63

VSS

Ground terminal

64

NC

I

Not used (fixed at “L”)

65

POS0

I

66

POS1

I

67

POS2

I

68

POS3

I

69

FLASH-W

I

Internal flash memory data write mode detection signal input terminal “L”: data write mode
Not used (fixed at “H”)

70

I2C SDA

I/O

Two-way data I

2

C bus with the FM/AM tuner unit (TUX1), RDS decoder (IC50) and electrical

volume (IC10)

71

I2C SCL

O

I

2

C bus clock signal output to the FM/AM tuner unit (TUX1), RDS decoder (IC50) and electrical

volume (IC10)

72

RCIN1

I

Rotary remote commander shift key input terminal

Tape position (EJECT/FF/REW/REV/
FWD mode) detect input from the tape
operation switch on the deck mechanism

POS0: “L”: EJECT mode, “H”: others mode
POS1: “L”: FF and FWD mode, “H”: others mode
POS2: “L”: REW mode, “H”: others mode
POS3: “L”: REV and EJECT mode, “H”: others mode