Transient Designer

6

Before connecting the T

RANSIENT

D

ESIGNER

switch power off at all

connected units.

The T

RANSIENT

D

ESIGNER

is fitted with XLR-connectors for balanced

operation. The following illustration shows the pin-wiring:

To ensure optimal signal quality, SPL has developed a new hybrid-
component balanced input/output stage using all laser-trimmed
resistors with a tolerance of 0.01%. This approach has resulted in
an exceptionally high CCMR (common mode rejection); -80 dB at
1kHz and -75 dB at 10 kHz.

Should the need arise to use the XLR connectors in an unba-

lanced system, pin 3 of the XLRs should be grounded. The follo-
wing illustration shows how to properly unbalance a balanced
signal:

Rear panel T

R

ANSIENT

D

ESIGNER

,model 9842

Connections

2

1

3

1

2

3

Pin wiring: XLR output

1 = GND, 2 = hot (+), 3 = cold (-)

Pin wiring: XLR input

1 = GND, 2 = hot (+), 3 = cold (-)

soundperformancelab

.com

TO REDUCE RISK OF F

IRE

OR EL

ECTRIC SHOCK DO

N

O

T E

XPOSE

THIS UNIT

TO RAIN OR MOIS

TURE.

DISC

ONNECT

MAIN

S

BEF

ORE REMO

VING C

O

VER.

VOLTAGE/

FUSE

XLR W

iring: 1 = GND/ 2 = (+)/ 3 = (–)

Output

4

Input

4

Output

3

Input

3

Output

2

Input

2

Output

1

Input

1

GND LIFT

AVIS: RISQUE DE CHOC ÉL

ECTRIQUE - NE P

A

S OUVRIR

RISK OF EL

ECTRIC SHOCK

DO N

O

T OPEN

C

A

UTION

Serial #

WARNING

Sound P

erformance Lab

SP

L electr

onics

GmbH

41

372 Niederkrüchten

Germany

Made in Germany

230

V

50 Hz

Fuse: 200

m

A

115

V

60 Hz

Fuse: 400

m

A

230

V

Input

4

Output

4

Input

3

Output

3

Input

2

Output

2

Input

1

Output

1

Advertising