5 specifications, 1 electrical specifications – Spectra Logic TAC/COM SERIES User Manual

Page 19

Advertising
background image

SM06 Rev. 4.10

Tac/Com Control Head Manual


1.5

Specifications

1.5.1

Electrical Specifications

Input

Power:

16-33

Vdc.


Current:

0.25 A/LED Control 250 Series

0.35

A/LED

Control

350

Series

0.45

A/LED

Control

450

Series

0.15

A/LCD

Control

400

Series

+0.075 A/Interface Card Installed (for all types)

+0.250

A/28

Vdc

for

panel

lighting


Values above are maximum, display set to full intensity.


Panel

Indicators:

Two-colour LED indicates: TX - Green

RX (SQ) - Orange


One LED per radio, except when the interface

supports separate guard controls (‘U’, ‘V’, etc.), in

which case a second LED is provided for the guard

receiver.


Channel

Storage:

CH-series

(Tac/Com I)

32/56 Channels per radio


TH series (Tac/Com II)

128 Channels per radio


Data

Interface:

Programming

via

standard RS-232 from a PC (NAT

software), or front panel for all functions.


Scanning:

NT -series transceivers: 90 channels/second/radio.

NTX -series transceivers: 10-20 channels/second/radio.


Modes are LIST, PRIORITY, LIST + PRIORITY.
Priority monitoring is 3 times/second for 10-15 ms sample.
Radio will re-channel to the priority channel if traffic is
detected, and returns to the monitor channel after a 2
second latency.

All CTCSS tones or DPL codes are inactive during
scanning (due to lock delay).


Other

scanning

parameters depend on the radio type.

Jan 4, 2006